TOC and TNb analyses with extra
versatility
The Multi N/C series of catalytic combustion analysers from Analytik Jena UK claim 'extraordinary' versatility for TOC (total organic carbon) and TNb (total bound nitrogen) measurement
The novel design of the Multi N/C series provides a TOC measuring range from 2ppb up to 30000ppm without dilution and a fully integrated double furnace for the analysis of solids or liquids The exceptional measurement range is achieved using a multi-channel detector, which features three detectors to cover the entire measurement range and a reference detector
This article was originally published on Laboratorytalk on 12 Feb 2008 at 8.00am (UK)
Related stories
TOC and TNb determined simultaneously
Multi N/C series of catalytic combustion analysers from Analytik Jena UK have been designed for the fully automatic determination of bound carbon (TIC/TOC, TC, NPOC, POC) and/or total nitrogen (TNb)
Flame AA spectrometer comes with injection module
Versatile combination of Novaa 300 and SFS6 is suited for small sample volumes, samples with high acid content or a difficult background matrix, and gives accurate and reproducible analytical results
AA spectrophotometers in 2008 UK roadshow
Analytik Jena UK will be holding a UK-based roadshow during July 2008 featuring the ContrAA series of high resolution continuum source (HR-CS) atomic absorption spectrophotometers
The system is equipped with automatic detector selection, auto drift compensation and auto- zeroing.
Automatic detector selection means that samples can be analysed without dilution.
An easy to use and low maintenance self check system is used to control all system functions.
High accuracy results are ensured using patented Vita technology, which automatically determines the retention time of the sample in the analyzer.
This is achieved by real time measurement of the gas flow to allow the detector signal to be automatically corrected for variations in the flow.
VITA technology not only leads to good accuracy and sensitivity but also excellent repeatability.
VITA improves repeatability from typically 5-10% in the 0.5 - 1.0mg/l range and 3-5% in the 1000 to 5000mg/l range to 1-2% across the measuring ranges.
In addition, Vita significantly reduces the intervals between calibrations to around six months.
Multi N/C series instruments can be calibrated across the entire detection range using a single standard sample, eliminating the need for a large number of standard reference materials.
Additional versatility comes from the double furnace configuration which can be oriented vertically for liquid samples and horizontally for solid samples.
It is simple to switch between the two configurations.