Product category:
Microscope supplies and accessories
News Release from: Carl Zeiss | Subject: Radiance2100
Edited by the Laboratorytalk Editorial
Team on 18 March 2003
Fret microscopy in living cells
Study describes confocal and multi-photon fluorescence resonance energy transfer microscopy to characterise the dimerisation of transcription factors in living mouse cells
Details of a study describing the use of confocal and multi-photon Fret (fluorescence resonance energy transfer) microscopy techniques to characterise the dimerisation of transcription factors in the nucleus of living mouse pituitary cells have been published in a Bio-Rad application note Although several in vitro biochemical methods exist to study protein-protein interactions, it is not clear to what extent they accurately reflect behaviour in living cells
This article was originally published on Laboratorytalk on 9 Oct 2002 at 8.00am (UK)
Related stories
Broad-spectrum laser microscopy
Rainbow laser scanning microscope promises full sensitivity spectral detection without limitations or compromise
Tracking movement of nucleolar proteins
The use of fluorescence rcovery after potobleaching (Frap) to study the movement of a nucleolar protein in HeLa cells has been described in an application note
Using a Bio-Rad Radiance2100 system, Periasamy of the University of Virginia, USA, describes the molecular behaviour of CFP- and YFP-tagged C/EBPa transcription factor and the use of Fret to quantify the formation of transcription factor C/EBPa dimers in the nucleus of these living cells.
Fret involves the transfer of energy from a donor fluorophore to an acceptor fluorophore resulting in emission from the acceptor as a result of donor excitation.
For transfer to take place the donor and acceptor molecules must be very close (<10nm) and measurement of the Fret signal provides spatial information about the two molecules at a resolution beyond the limits of conventional microscopy.
Dr Periasamy describes the advantages of using multi-photon Fret in work with living cells adopting a Coherent Ti:sapphire laser system.
The wide tuning range (700-1000nm) enables excitation of most fluorophore pairs while excitation in the infrared region causes significantly less intracellular damage.
The authors have also developed software dedicated to correcting contamination of the Fret signal by spectral bleed-through and fluorophore expression level variation in living cells and tissues.
The full details of the study may be read in Bio-Rad's Application Note 36, which is available free of charge.
The Radiance2100 confocal and multi-photon system is available exclusively from Bio-Rad Cell Science Division.
• Carl Zeiss: contact details and other news
• Email this article to a colleague
• Register for the free Laboratorytalk email newsletter
• Laboratorytalk Home Page
