Visit the AM Technology web site
Click on the advert above to visit the company web site

Product category: Spectroscopy software
News Release from: Cerno Bioscience | Subject: MassWorks sClips
Edited by the Laboratorytalk Editorial Team on 22 January 2008

Accurate formula ID on ion trap mass
spectrometer

Request your FREE weekly copy of the Laboratorytalk email newsletter. News about Spectroscopy software and more every issue. Click here for details.

Cerno Bioscience, in cooperation with Sabic Innovative Plastics, has succeeded in demonstrating the ability to perform formula ID on a Thermo Scientific LCQ Deca Max ion trap mass spectrometer

Using MassWorks sClips (self calibrated lineshape isotope profile search), the latest addition to the MassWorks mass spectrometry software suite, the researcher, Christian Wold, was able to identify a set of trial compounds to within a top few compounds from a list of hundreds of formula candidates MassWorks was originally launched in 2006, and received the prestigious Editors' Choice Bronze award at Pittcon 2006

MassWorks is an easy-to-use post acquisition software system using Cerno's patented MSIntegrity calibration technology to work directly with data from a wide range of mass spectrometers.

Formula ID normally requires accurate mass measurements typically provided by high resolution time-of-flight (TOF), Orbitrap or FT-ICR instrumentation.

Ion traps typically cannot provide accurate mass measurements due to physical limitations of the ion trap analyser, particularly in the older 3D trap designs such as the instrument used in this study.

However, the cooperation with Wold has demonstrated that by carefully controlling the ion trap conditions, it is possible to attain high spectral accuracy which is suitable in itself for Formula ID.

The approach utilises Cerno's sClips technology to correct the instrument line-shape and allows highly accurate matching of the isotope pattern of the unknown ion against theoretically calculated ion candidates.

One of the benefits of the approach is that it requires no known calibration ions, and instead utilises the ion traps ability to scan in high resolution mode to resolve the isotope peaks.

The monoisotopic peak of the analyte ion can then be used to correct the measured isotope pattern for accurate matching to theoretical spectra.

Ming Gu, VP of research for Cerno Bioscience comments: "We were quite surprised by the level of performance achievable on the 3D trap design.

"This work is a good indication that even better results should be obtainable with more modern linear ion trap designs".

The approach extends the versatility of ion trap instruments by enabling them to provide formula identification, a capability previously not thought possible.

Cerno Bioscience: contact details and other news
Email this article to a colleague
Register for the free Laboratorytalk email newsletter
Laboratorytalk Home Page

Search the Pro-Talk network of sites

Visit the AM Technology web site