News Release from: Lambda Advanced Technology | Subject: ContrAA 300
Edited by the Laboratorytalk Editorial
Team on 02 March 2006
Completely new approach to flame atomic
absorption
Novel approach means that all atomic absorption lines from 190-900nm are available from a single light source without the necessity for a different hollow cathode lamp for each element of interest
A completely new approach to flame atomic absorption spectrophotometery (AAS) has been launched in the UK by Lambda Advanced Technology The ContrAA 300 from Analytik Jena combines the simplicity of AAS with the speed and flexibility of ICP spectrometry by utilising a high resolution continuum light source in conjunction with a high resolution double Echelle monochromator for the first time in the technique
This article was originally published on Laboratorytalk on 10 Mar 2003 at 8.00am (UK)
Related stories
Prodigious performance from ICP spectrometer
Using a novel large format programmable array solid state detector and a high-dispersion Echelle spectrometer for low noise and interference-free low detection levels
PPT-level mercury determination
Using the principle of cold vapour atomic absorption spectrometry, this system can detect mercury in a variety of samples down to one part per trillion
This increases sample throughput, improves detection limits and reduces costs.
This novel approach means that all atomic absorption lines from 190-900nm are available from a single light source without the necessity for a different hollow cathode lamp for each element of interest.
Each sample can be analysed sequentially for each element instead of having to measure one element on each sample, change lamps, then measure the next element on each sample and so on.
The high intensity light source and back-thinned CCD detector bring enhanced sensitivity and improved detection limits.
For example, 0.1 parts per million Pb can be detected in 1g/l Fe solution.
The system also provides simultaneous real time registration of both analyte and background, using a pixel referencing technique instead of complex and expensive D2 or Zeeman background correction methods.
This technique corrects for lamp drift, variations in thermal emission and unspecified background absorptions, leading to faster and more accurate measurements.
To cover the full range of elements accessible by flame AAS, 67 different lamps would be required.
Not only is this an expensive option, especially for rarely analysed elements, but most instruments will hold a maximum of just eight lamps on an adjustable turret.
All lines are available on the ContrAA 300 from a single, high intensity xenon short-arc lamp. Request a free brochure from Lambda Advanced Technology ...