The determination of water in hair
It is not easy to tell a good shampoo from a poor one, especially when advertising concentrates on fragrance and foam rather than cleansing and moisturising ability
People expect a lot from shampoos and conditioners Unfortunately, it is not easy to tell a good shampoo from a poor one
This article was originally published on Laboratorytalk on 5 Feb 2002 at 8.00am (UK)
Related stories
Surface moisture or water of crystallisation?
Metrohm's 774 oven sample processor can discriminate between free water on the surface and bound water within the crystsalline lattice of samples
Analysis of mercury in waters using voltammetry
Jonathan Bruce, Applications Manager for Metrohm UK, provides this comprehensive introduction to analysis of mercury in waters
Cost, fragrance, and lots of foam is what most people look for in shampoo products.
Lather and foam is of little importance, but they often get the most attention.
Foaming occurs when surfactant molecules gather around air instead of oil.
Further reading
On-line lactic acid analysis of dairy products
Determination of lactic acid in milk and associated dairy products is an extremely common laboratory application and has key product quality control use in a modern dairy
Analysis of sugars in chocolate bars
The analysis of the different sugars present in a bar of chocolate can reliably and affordably be quantified using pulsed amperometric detection (PAD) with the 817 Bioscan from Metrohm
Determining aluminium level in deodorant matrix
Body odour is never pleasant, and we've all been crammed on a train or been in a busy shopping centre and noticed the distinctive smell of stale sweat
The result is millions of tiny bubbles.
Obviously, the air bubbles are using the surfactants that should be removing dirt and oil.
We have all seen shampoo advertisements showing happy, beautiful people taking showers with their heads heaped high with mounds of lather.
These images have taught the public to associate lather with cleansing ability.
The truth is, lots of foamy lather only means too much shampoo was used.
Excess foam equals waste.
Sebum and other oils quickly destroy foam.
Ideally, the head should have just enough lather to lubricate the scalp and hair.
This will help the fingers massage the shampoo more effectively into the hair.
Fragrances and foaming qualities are not good ways to evaluate shampoos and conditioners.
A good way to evaluate the moisturising performance of the shampoo and conditioners is to determine the water content of the hair before and after treatment with the relevant product.
A sample of hair is taken from the head prior to treatment.
The hair is then washed with the shampoo/conditioner, dried and a further sample is cut from the hair.
Fairly large samples of hair were taken.
Historically the analysis of water in hair was not only time consuming but very inaccurate.
The sample was typically digested with hot acid and then added to a solvent (typically methanol).
This sample solution was then injected into a volumetric Karl Fischer instrument where the moisture content was determined.
At every step errors were introduced and subsequently poor relative standard deviations were achieved on the results.
However, with a unique technique developed by Metrohm, analysis times are shorter and the reproducibility of results is significantly better.
Using the 774 oven sample processor in conjunction with the 831 KF Coulometer analysis times are typically 3-5 minutes and RSDs on results are less than 1%, and more importantly for the hair donor, sample sizes are tiny.
The hair is weighed into a vial and the top is sealed (crimped).
This sample is then introduced into an oven where the water evolved is titrated in the KF coulometric cell.
The refined methodology of the 774 OSP brings decisive advantages;.
Strictly reproducible analysis conditions for all samples, this is shown by the considerably improved precision of the results.
Manual sample preparation is reduced to a minimum, just weigh, crimp and analyse.
Considerable savings in time and money, less reagent costs for example, no more acid and solvent extraction.
No contamination of the oven, consequently there is no carryover and memory effects.
Improved water release from the sample as the carrier gas does not just pass over the sample but directly through it.
Fast analysis times; typically three minutes, and up to 35 samples at a time.
Metrohm also has applications where the bound and unbound moisture can be determined separately. Request a free brochure from Metrohm UK ...