Product category:
Titration equipment
News Release from: Metrohm UK | Subject: 855 robotic fluoride analyser
Edited by the Laboratorytalk Editorial
Team on 23 January 2006
Robotic fluoride analysis
Thanks to the flexible programming the Tisab is added fully automatically before the sample is analysed with an accuracy and precision that is not influenced by the user
Metrohm has produced the first off-the-shelf, dedicated robotic fluoride analyser Historically, bench-top fluoride analysis can be very time consuming
This article was originally published on Laboratorytalk on 2 Jul 2008 at 8.00am (UK)
Related stories
Analysis of mercury in waters using voltammetry
Jonathan Bruce, Applications Manager for Metrohm UK, provides this comprehensive introduction to analysis of mercury in waters
On-line lactic acid analysis of dairy products
Determination of lactic acid in milk and associated dairy products is an extremely common laboratory application and has key product quality control use in a modern dairy
With the Metrohm 855 robotic fluoride analyser, the analyst no longer must carry out the following:.
Ensure the ion selective electrode (ISE) is conditioned and stored correctly.
Calibrate the ion meter with standards before measurement.
Further reading
Analysis of sugars in chocolate bars
The analysis of the different sugars present in a bar of chocolate can reliably and affordably be quantified using pulsed amperometric detection (PAD) with the 817 Bioscan from Metrohm
Determining aluminium level in deodorant matrix
Body odour is never pleasant, and we've all been crammed on a train or been in a busy shopping centre and noticed the distinctive smell of stale sweat
Fast, accurate, Karl Fischer for difficult samples
The water content of many samples is difficult to determine because they are only slightly soluble in alcohols, contaminate the titration cell or undergo side reactions with the Karl Fischer reagent
Manually add a exact volume of Tisab (total ionic strength adjustment buffer).
Rinse and condition electrode between each measurement.
For routine high volume rapid fluoride determination, the 855 fluoride analyser is the perfect answer, says the company.
Up to 59 sample positions.
Everything has been taken into consideration.
The measurement is achieved by standard addition and the Tisab is added automatically by the 855.
Applications for the system.
Some recent examples of samples the system has been used for indicate the possible range of analysis.
Landfill leachates, 0.1ppm and above.
Red wine 0.2ppm.
Cooking salt 52ppm.
Mouth-wash 250ppm.
Toothpaste 1300ppm.
Work is carried out at a fixed ionic strength in the fluoride determination.
The sample is treated with an exactly defined volume of Tisab solution (Tisab = total ionic strength adjustment buffer).
Previously this buffer had to be added manually.
An additional Dosino is incorporated in the robotic fluoride analyser to carry out the addition of this buffer.
Thanks to the flexible programming the Tisab is added fully automatically before the sample is analysed with an accuracy and precision that is not influenced by the user.
A second Dosino is used for standard addition to achieve a measurement.
Mounted directly on the reagent bottle, the Dosino is the perfect way of dosing and space-saving.
The sensor combination of crystal membrane fluoride ISE and a Long Life ISE reference electrode leaves nothing to be desired.
The perfectly matched construction of this electrode pair can determine the fluoride content of the sample precisly, even at a low sensor immersion depth.
At low ion concentrations and low ionic strengths and most importantly for repeated determinations in automated systems, a stable, reproducible reference potential is crucial.
The 6.0750.100 Long Life reference electrode is has a fixed ground-joint diaphragm which provides a constant electrolyte flow, this is very important as the ionic strength and stirring rate have a minor influence on results.
In addition to the fluoride measurement accessories, the 855 robotic analyser comes with an application package containing all the necessary instructions and flouride methods including many determination examples in the database.
The methods provided are already included in the Tiamo software as templates.
The data produced is managed in a well laid out and easy to use database.
Tiamo offers everything required for high sample throughput - and more, says Metrohm.
From flexible method parameters up to data storage in a professional database.
If-Then-Else links, complex calculations, user administration and working under FDA-conditions are easy with this modern titration software.
In Summary.
Up to 59 samples per rack.
The 855 adds the standard and Tisab.
The 855, rinses the electrodes after every determination.
The 855 stores the electrode in the correct medium between runs.
There is state-of-the-art software control and data storage.
The integration of the ion meter, sample processor and Dosinos ensure little bench-space is taken up. Request a free brochure from Metrohm UK ...
• Metrohm UK: contact details and other news
• Email this article to a colleague
• Register for the free Laboratorytalk email newsletter
• Laboratorytalk Home Page