Metrohm UK provides Karl Fischer
solution
The 832 KF Thermoprep system from Metrohm UK is the result of an improvement of the conventional Karl Fischer drying oven technology
Many substances, such as plastics or inorganic salts, release water only very slowly or at high temperatures Therefore they are not suitable for direct Karl Fischer titration
This article was originally published on Laboratorytalk on 2 Jul 2008 at 8.00am (UK)
Related stories
Analysis of mercury in waters using voltammetry
Jonathan Bruce, Applications Manager for Metrohm UK, provides this comprehensive introduction to analysis of mercury in waters
On-line lactic acid analysis of dairy products
Determination of lactic acid in milk and associated dairy products is an extremely common laboratory application and has key product quality control use in a modern dairy
Another problem is the low solubility of certain samples in alcohols.
In these cases, traditional methods recommend the use of harmful solubilisers or complex sample preparation steps.
Direct introduction of the sample into the titration cell can also contaminate the cell making it necessary to frequently change the reagents and clean the cell.
Further reading
Analysis of sugars in chocolate bars
The analysis of the different sugars present in a bar of chocolate can reliably and affordably be quantified using pulsed amperometric detection (PAD) with the 817 Bioscan from Metrohm
Determining aluminium level in deodorant matrix
Body odour is never pleasant, and we've all been crammed on a train or been in a busy shopping centre and noticed the distinctive smell of stale sweat
There are the various substances (for example ascorbic acid) that undergoes interfering side reaction with the KF reagents leading to incorrect results.
These problems can be resolved with the KF Oven Method.
With the method the substances to be examined are heated in a tube oven; carrier gas then transports the release water into the titration cell where it is determined by Karl Fischer titration.
As only the water releases the titration cell and the sample does not come into contact with the KF reagents, undesired side reactions and matrix effects are ruled out.
The 832 KF Thermoprep applies the vial technique.
The samples are no longer introduced into the oven in weighing boats, but their own, perfectly sealed sample vial.
This gives the advantage of the analysis being performed under strictly reproducible conditions, which translates into improved precision.
Moreover, because sample preparation is reduced to a minimum, considerable time savings are obtained.
Sample preparation is straightforward and merely involves weighing the sample into the vial and sealing it with a crimping tool.
The hermetic sealing of the vessels with PTFE-coated septa prevents interferences due to humidity absorption from the ambient air.
For this reason, vials are used as standard in production plants.
The vial used in production areas can be of varying diameter and height.
In addition the dimension tolerances of the sample vessels depend on the manufacturer.
Metrohm have taken this into account in the design of the company's oven block, which has a variety of inserts and adapters to accommodate most customers requirements.
The 832 KF Thermoprep is now available with an optional heat able transfer tubing.
In particular, when the water is determined in the higher percentage range or at high temperatures, the water that is released from the sample can form a condensate in the transfer tubing, which produces too low and or erratic results.
In such cases, it is recommended to use a heated tubing guaranteeing complete transfer of the released water to the titration cell. Request a free brochure from Metrohm UK ...
• Metrohm UK: contact details and other news
• Email this article to a colleague
• Register for the free Laboratorytalk email newsletter
• Laboratorytalk Home Page