Toxin detection in a time of cholera
Cholera continues to be a major public health concern in developing countries, with at least seven pandemics recorded - new tests help determine virulence are faster than before
The scale of the problem.
Cholera continues to be a major public health concern in developing countries.
The disease is a toxin-mediated bacterial infection, caused by certain serogroups of Vibrio cholerae, that has the ability to cause outbreaks of epidemic proportions.
In the last 200 years there have been at least seven cholera pandemics, of which the latest still continues.
The current pandemic, which began in 1961 in Indonesia, has now circled the globe, affecting countries in Asia, Africa, Europe and South America.
In 2003 outbreaks were reported in many countries, including South Africa, Mozambique, the Democratic Republic of the Congo, Liberia and Iraq.
Up to the early 1990s, of over 100 different serogroups, only V cholerae serogroup O1 was known to be capable of causing cholera.
However, 1992 saw the unprecedented appearance of a new, non-O1 epidemic strain in India.
This was later to be identified as V cholerae serogroup O139, and the outbreaks caused by this new strain have been heralded by some to be the start of the eighth cholera pandemic.
Historically, the disease has been associated with the movement of large groups of people.
This is illustrated in the current cholera outbreak that is ravaging Liberia's capital, Monrovia.
Since June 2003 over 10,000 people have been affected and by mid September, over 2000 new cases were being reported every week, mainly amongst displaced people.
This is thought to be a result of the movement of thousands of people to the capital, combined with insufficient water and poor sanitation.
Cholera disease.
The cholera enterotoxin produced by V cholerae serogroups O1 and O139 causes an increase in cAMP within the cells of the gastro-intestinal tract, resulting in the secretion of water and electrolytes.
The disease manifests with profuse watery diarrhoea, vomiting and dehydration, often with associated leg cramps due to electrolyte imbalance.
The disease can lead to severe dehydration and death if treatment is delayed.
It is estimated that approximately 75% of cholera cases are asymptomatic.
Of the 25% that present symptoms, the majority are mild to moderate.
Less than 10% develop typical cholera and in only 2% of cases does the illness progress to life-threatening 'cholera gravis'.
In severe cases, death may occur within hours of the onset of disease.
Cholera is transmitted through drinking water or eating food contaminated with toxin-producing V cholerae.
It spreads rapidly in areas with inadequate treatment of sewage and drinking water.
Treatment.
Cholera is life threatening, but can be treated easily.
Treatment involves immediate replacement of fluids and salts, either orally or, in severe cases, intravenously.
With prompt rehydration the case fatality rate is less than 1%, but in an unprepared community the death toll may be as high as 50%.
Antibiotics may shorten the course of the disease and reduce the severity of the symptoms.
However, antibiotic resistance has been a growing problem in many parts of the world.
Consequently, antibiotic susceptibility should be determined at the beginning of an epidemic and monitored periodically throughout.
Identification.
Diagnosis of cholera is confirmed by the isolation of V cholerae O1 or O139 from stool culture.
Isolates should be serotyped and they can also be tested for toxin production.
The detection of cholera toxin (CT) production is an important indicator of virulence.
When the first case of imported V cholerae serogroup O139-associated cholera occurred in the USA in 1993, standard laboratory techniques determined that this was a non-O1 strain and yet found it to produce toxin.
With the emergence of V cholerae O139, the importance of a serogroup acquiring the potential to cause epidemics has become evident.
The danger of other toxin producing serogroups emerging should not be discounted.
Existing serological methods may not be able to detect a new serogroup.
However, confirmation of the production of CT would alert scientists to the possibility of a new epidemic strain.
Testing for bacterial toxins.
The Oxoid reversed passive latex agglutination (RPLA) toxin detection kits are convenient, simple to perform assays that give clear, easy to read results in less than 24 hours - significantly faster than alternative methods.
Latex particles are sensitised with antibodies to the target toxin.
In the presence of that toxin, the latex particles agglutinate to form a clearly visible lattice structure.
These tests are highly sensitive and specific, requiring minimal effort and no specialised equipment, making them ideal for use outside larger reference laboratories.
In addition to detecting Vibrio cholerae enterotoxin, the Oxoid VET-RPLA test will detect E coli heat-labile enterotoxin.
Tests are also available for staphylococcal enterotoxins A, B, C and D (SET-RPLA), Bacillus cereus enterotoxin (diarrhoeal type) (BCET-RPLA), E coli verotoxins VT1 and VT2 (VTEC-RPLA), staphylococcal toxic shock syndrome toxin (TST-RPLA) and Clostridium perfringens type A enterotoxin (PET-RPLA).
In addition, Oxoid offers a competitive enzyme immunoassay kit for E coli heat-stable enterotoxin (E coli ST EIA), and a rapid 30 minute test for Clostridium difficile toxin A (C difficile toxin A test).
Not what you're looking for? Search the site.
Tel (0) 1256 841144
-
Prospect tests for most gastroenteritis causes
Oxoid has extended the Prospect range of qualitative enzyme immunoassays. -
Oxoid screening media help control infection
Oxoid has announced the availability of two chromogenic media in the Brilliance resistant screening agar range. -
Oxoid runs free UK infection-control seminar
Oxoid has announced that the next Oxoid Infection Control Seminar will take place on 2 June 2009 at The Belfry in West Midlands, UK. -
Oxoid develops tests for fast patient diagnosis
Oxoid has exhibited its latest products for clinical microbiologists at the European Congress of Clinical Microbiology and Infectious Diseases (ECCMID) in Helsinki. -
Brilliance Agar solves problem of MRSA screening
Oxoid is supplying Brilliance MRSA Agar to hospital laboratories worldwide to solve the problem of MRSA screening.
Articles by product category
-
Analytical instruments (8,805)
- Analytical instruments (13)
- Chemical analysis equipment (631)
- Chromatographs: gas (241)
- Chromatographs: liquid, ion, gel, HPLC (427)
- Chromatography accessories (503)
- Gas analysis equipment (219)
- pH and conductivity meters (114)
- Cameras and imaging systems (820)
- Electron microscopy systems (209)
- Optical microscopes (448)
- Microscope supplies and accessories (558)
- Mass spectrometers (458)
- Spectroscopy (535)
- Other analytical instruments (592)
- Particle size analysis equipment (555)
- Microplate readers (39)
- Temperature, pressure and flow measurement (262)
- Spectrophotometers (273)
- Titration equipment (655)
- Ultrasound equipment and ultrasonic spectroscopy (118)
- Viscometers and rheometers (346)
- Oscilloscopes (83)
- Mechanical testing equipment (492)
- Test and calibration instrumentation (214)
-
Life sciences and clinical laboratory equipment (3,579)
- Life sciences and clinical laboratory equipment (3)
- Clinical chemistry analysis (898)
- Nucleic acid sequencing and synthesis (637)
- Genomics (459)
- Proteomics (450)
- Assay kits (185)
- Microbiology (383)
- Polymerase chain reaction (PCR) (240)
- Cell/tissue handling and counting (324)
-
Computer hardware (826)
- Computer hardware (7)
- Dataloggers (302)
- I/O devices (362)
- Monitors and peripherals (50)
- Process control and networking (79)
- PLCs (26)
-
Industry news (19)
- Industry news (19)
-
Laboratory equipment and wares (5,937)
- Laboratory equipment and wares (5)
- Safety and ventilation equipment (322)
- General lab equipment (831)
- Workstations (61)
- Detectors, sensors and probes (375)
- Lab automation equipment and robotics (651)
- Laboratory furniture and storage (151)
- Gas handling (125)
- Heating: ovens, furnaces, autoclaves (331)
- Fermentation and incubation equipment (73)
- Microplates/microarrays and readers (397)
- Microfluidics/Lab-on-a-chip systems (142)
- Distillation equipment (16)
- Sampling equipment (156)
- Environmental chambers (88)
- Fume cupboards ductless (79)
- Laboratory glassware (400)
- Liquid handling (415)
- Cooling: refrigeration (198)
- Washing and sterilisation equipment (207)
- Fume cupboards ducted (31)
- HTS and combinatorial chemistry equipment (57)
- Evaporation equipment (166)
- Weighing and balancing (240)
- Centrifuges (47)
- Water purification (213)
- Laboratory plasticware (160)
-
Laboratory supplies and consumables (1,271)
- Laboratory supplies and consumables (2)
- Culture media (119)
- Reagents and catalysts (169)
- Antibodies (203)
- Cleaning products (65)
- Reference standards (178)
- Chemicals and biochemicals (534)
-
Pumps, Valves, Filters (708)
- Automated Valves (66)
- Filtration equipment and supplies (176)
- Metering pumps (109)
- Other pumps (63)
- Peristaltic pumps (65)
- Vacuum pumps and compressors (144)
- Manual Valves (85)
-
Services (2,989)
- Contract research (889)
- Laboratory and scientific exhibitions and conferences (230)
- Laboratory and scientific recruitment (26)
- Laboratory and scientific consultancy services (288)
- Laboratory and scientific training and education (413)
- Laboratory building and design (50)
- Laboratory and scientific manufacturing services (136)
- Laboratory and scientific professional organisations (482)
- Laboratory and scientific books and publishing (475)
-
Computer software (2,882)
- Computer software (4)
- Chemical modelling software (181)
- Laboratory and scientific databases (327)
- Instrument control software (320)
- Laboratory information management system (LIMS) (721)
- Mathematical software (163)
- Process control and networking software (52)
- Data acquisition software (171)
- Chromatography software (284)
- Spectroscopy software (92)
- Analytical, statistical and report generating software (284)
- Data management software (283)
