Product category:
Vacuum pumps and compressors
News Release from: Rietschle Thomas
Edited by the Laboratorytalk Editorial
Team on 12 July 2002
Atex certification for dry vacuum pump
Unit has now passed the necessary inspections and tests for use in potentially explosive atmospheres; in Zone 0T4 gas group IIb and Zone IT4 gas group IIb areas
Rietschle's cool running Twister series has been certified by an EC Notified Body as complying with the requirements for Category 1 of the Atex Equipment Directive 94/9/EC, which comes into force from June 2003 Thought to be one of the simplest screw vacuum pump designs on the market, the Twister has now passed the necessary inspections and tests for use in potentially explosive atmospheres; in Zone 0 T4 gas group IIb areas (internal hazard zone rating), and in Zone I T4 gas group IIb areas (external hazard zone)
This article was originally published on Laboratorytalk on 1 Aug 2000 at 8.00am (UK)
Related stories
First claw pump for pressure/vacuum in one stage
Rietschle's Zephyr multi-claw series are highly efficient, dry-running pressure/vacuum pumps, air compressors, and vacuum pumps, with applications across industry.
Pump rapidly pulls down vacuum in reactor vessel
In developing a new high-performance, chlorine-free, lubricating oil dispersant at its Bromborough plant, Lubrizol needed a reliable vacuum solution and turned to Rietschle
The low temperature performance of the pump is the result of a patented, progressive pitch screw with internal compression - rather than complex computer control of the drives, or cooling of the screws.
This highly efficient design also offers up to 30% savings on power consumption, compared with standard screw sets.
One unwanted consequence of running at these low internal temperatures is the likelihood of process vapours condensing within the pump; possibly resulting in corrosion.
Rietschle has overcome this in the Twister by applying an anti-corrosion coating of 'Niflon' or 'Nifa' to process wetted parts.
Rietschle's process systems manager, Dave Laurenson, said that a further, forthcoming Atex Directive (1999/92/EC) would be implemented in July 2006.
"This could mean additional modifications are needed to existing 'pre-Atex' plant, where an 'assessment of explosion risk' determines that a potential hazard exists; for example by fitting flame arresters.
We are happy to survey customers' plants to advise on any necessary measures as a guide to compliance with current and future legislation.".
• Rietschle Thomas: contact details and other news
• Email this article to a colleague
• Register for the free Laboratorytalk email newsletter
• Laboratorytalk Home Page