Visit the Lablogic Systems web site
Click on the advert above to visit the company web site

Product category: I/O devices
News Release from: Strategic Test | Subject: UltraFast PCI cards
Edited by the Laboratorytalk Editorial Team on 10 May 2007

Dual time base mode for PCI waveform
digitiser

Request your FREE weekly copy of the Laboratorytalk email newsletter. News about I/O devices and more every issue. Click here for details.

ABA Mode allows cards to be configured for slow continuous recording, similar to a data logger, switch to high-speed sampling on detection of the trigger event, and then return to slow recording

Strategic Test has introduced a new dual time base option for its line of UltraFast oscilloscope/digitiser PCI cards A pre-trigger can be set so that data is recorded prior to the trigger event at the fast sample rate

The main uses for the ABA mode are applications that need a recorded history of a process, both leading up to and after the trigger event.

For example, safety critical applications and quality testing can require continuous monitoring and high-speed recording in the event of a process or production failure.

While it is possible to pre-define the total number of samples to record so that the measurement card stops by itself, the most common use is likely to be where the measured data is continuously recorded to hard disk for audit trails.

The maximum speed that data can be recorded to hard disk is 200MBytes per second when using a Raid controller coupled to four S-ATA disks.

The slowest and fastest sampling rates that can be selected for the ABA mode are a function of the digitiser/oscilloscope card used.

Strategic Test offers more than 80 different PCI cards.

The minimum sampling rate is 1kSamples per second on all cards, while maximum sample rates for different cards are :.

16-bit resolution : 3, 1, 0.5, 0.25MSamples per second.

14-bit resolution : 50 or 20MSampes per second.

12-bit resolution: 200, 160, 100, 80, 50, 25, 10, 1MSamples per second.

8-bit resolution : 200, 100, 50MSamples per second.

Cards are available with between one and 16 channels.

The ABA mode is included in an option bundle together with the Multiple Recording (memory segmentation), Gated Sampling (start/stop sample clock by external TTL signal) and the Timestamp option.

The price for this combination is US$990.