Product category:
Chromatography accessories
News Release from: Thermo Fisher Scientific (Chromatography) | Subject: Biodiesel GC packages
Edited by the Laboratorytalk Editorial
Team on 28 December 2007
Biodiesel GC packages help EN and ASTM
compliance
Delivering complete automatic characterisation of pure biodiesel (B100), Thermo Scientific offers full compliance with EN and ASTM standards to certify quality of pure biodiesel for commercial trading
Thermo Scientific says its Biodiesel GC packages are the only ones available that are capable of providing integration and productivity for the three most commonly applied GC-based methods: EN 14103 for fatty acid methyl ester (Fame) characterisation and linolenic acid methyl ester determination; EN 14105 / ASTM D6584 for free and total glycerine content; EN 14110 for methanol content The interest in biodiesel as a clean burning alternative fuel produced from renewable sources has increased tremendously over the last few years, mainly due to its safer environmental impact in comparison with conventional petro-diesel
This article was originally published on Laboratorytalk on 15 Oct 2003 at 8.00am (UK)
Related stories
Free technical seminars on proteomics and LC-MS
Thermo Electron will host a series of free, educational and application-driven technical seminars across Europe from October to December 2003
HPLC column for HTP screening
These columns achieve average efficiencies of 70,000N/m, similar to standard microbore hardware efficiencies, but at a significantly lower cost
Offering high productivity and an easy-to-use fully automated comprehensive solution, the Thermo Scientific Biodiesel GC-EN is developed for use by biodiesel producers and also responds to users needs working in third party certification laboratories looking at applying the EN 14103, EN 14105 / ASTM D6584 and EN 14110 methods.
The comprehensive package contains everything required to comply with the official methods stated above, including a full set of reagents and consumables enabling the instant certification of biodiesel sample quality.
The package consists of a Thermo Scientific Trace GC Ultra equipped with an on-column inlet and flame ionisation detector (FID) used to run EN 14105 or ASTM D6584.
Further reading
Ion source for high-throughput proteomics analyses
Fast, automated, data dependent MS/MS analysis of protein digests and mixtures can be accomplished in a single experiment with this new system
Suite of products to transform proteomics research
Proteomics workstation based on mass spectrometer uses high performance proteomics autosampler and optimised column and method combinations for essential proteomics applications
High performance sampling for GC and GC/MS
Autosampler promises unique performance and increased lab automation flexibility while, at the same time, significantly extending productivity
The inlet is a true cold on-column injector, granting total recovery of heavy components like triglycerides and prevents any further risk of degradation of such labile substances.
A low dead volume purged metal tee has been specifically designed to ensure leak-free operations at very high oven temperatures, avoiding the use of less suitable glass press-fits.
A second Thermo Scientific Trace GC Ultra equipped with a PTV-backflush plus FID to run the EN 14103.
The backflush capability removes the heavier compounds and prevents them from entering and contaminating the column, thus extending its lifetime.
The same GC is also equipped with a split/splitless injection port and second FID channel to determine methanol content according to the headspace method EN 14110.
The headspace method is fully automated by the Thermo Scientific TriPlus HS autosampler, using a gas-tight syringe approach.
A Thermo Scientific TriPlus autosampler, to enable the automation of all the sampling methods on the two GC systems through two independent communication ports.
This results in the liquid and headspace sampling techniques running with the quick replacement of the sampling turret.
A Thermo Scientific data system (either ChromCard or ChromQuest), which controls the instruments and generates comprehensive reports with the shortest possible learning curve.
The Biodiesel Consumables kit, which includes three capillary columns and reagents, as well as the calibration standards needed to set-up the methods.
A complete Biodiesel GC productivity solution-ASTM solely dedicated to method ASTM D6584 is also available for the Thermo Scientific Trace GC Ultra.
This package provides a single-method solution for laboratories seeking to specialise in biodiesel analyses according to the ASTM method, or whose needs are limited to that methodology.
This complete package also comes with everything required to easily implement ASTM D6584 on the Trace GC Ultra, including a consumables kit.