The use of ion chromatography in biodiesel analysis
Metrohmcontact supplier
A recent study by the University of Campinas in Brazil has confirmed the suitability of ion chromatography (IC) for quality control of biodiesel.
In this study sodium, potassium, calcium, and magnesium cations in biodiesel were quantitatively determined by IC using conductometric detection.
The quality of the results was confirmed in terms of accuracy by analyzing samples of the same kind by Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) for comparison.
Pointing out one of their key findings, the authors state «that the proposed ion chromatographic method for the determination of Na , K , Mg2 and Ca2 in biodiesel offers statistically equivalent results to those of the ICP-OES procedure.
While the benefits of sophisticated methods such as ICP-OES for elemental analysis are acknowledged, the article continues to mention several inherent advantages of IC when it comes to the quality control of biodiesel.
Thus the authors point out the relatively low cost of this analytical technique since it is not necessary to use expensive reagents or solvents or to consume specialty gases, while the equipment can be installed in a small space in the laboratory.
Summarising additional benefits of IC, the researchers saw further potential for ion chromatography stating that due to its sensitivity and to the possibility of simultaneous multi-element determination, the ion chromatography method requires only small amounts of sample.
The ion chromatographic analyses in this study were performed on a Metrohm 761 Compact Ion Chromatograph using a Metrosep C4 – 100/4.0 column.
A PDF file is available from Metrohm above
More stories
Metrohm and FOSS enter strategic alliance
A new agreement with FOSS is set to make Metrohm the sole global distributor of FOSS NIR instruments.
Metrohm launches QuickTOCpharma weblink
Metrohm has introduced the QuickTOCpharma system for the detection of total organic carbon (TOC) in pharmaceutical water
Metrohm introduces its entry-level autosampler weblink
Metrohm has increased its automation portfolio for ion chromatography with the launch of the 919 IC entry-level autosampler
Compact titrator suitable for routine analysis downloadweblink
Metrohm has introduced the Ti-Touch, a compact titrator for routine analysis.
Metrohm MIPT technique in ion chromatography weblink
Metrohm has released a technical article/application note focusing on the use of its Metrohm Intelligent Partial Loop (MIPT) technique in ion chromatography.